Protective Devices and Systems for Heavy Duty Applications

 In the automation process and control industry, it becomes necessary to reduce equipment-related downtime. There are such heavy-duty machines and applications, that actually cannot afford sudden shutdown, sudden power-cut, and fluctuation in power and current. That is why there are protective and predictive devices such as high resistance grounding , arc flash relay, potentiometer, and alarm panel, et cetera. Let us discuss some of these. HRG HRG is a short form of high resistance grounding. And this type of system is an electrical supply system to control ground-fault voltage on driven equipment. This system is installed to reduce the probability of arc flashes which is basically light and heat produced as part of an arc fault. This device functions to provide unmatched switchgear protection by reducing arc flash energy. It acts as a tool to prevent faults in medium and low-voltage switchgear. Potentiometer Mostly used in applications such as speed controls, flow meters, and tens...

Top Quality High Resistance Grounding Supply Systems and Protective Devices

There is a lot of industrial automation and process control applications these days. For example, there are speed controls, tensioning motors, and flow meters et cetera. In order to ensure the controlled process, a type of device called a motorized potentiometer is utilized in such applications. It is one of the significant generator control devices. Functioning of Potentiometer This device functions by allowing automatic remote control in addition to the use of a manual control knob. It does not require any computer system or support to operate. This simple and easy to set-up device operates to maintain smooth performance, high linearity, resolution and reliable terminations. Considerations While Choosing This Device •         The resistance value which depends on the model type •         Wattage •         There are different types including conductive, plast...

Effective Ground Fault Monitor and Detector for Safety in Ships

Seaborne trade plays a significant role in the global economy and expanding continuously. In fact, 90% of trade is performed through the shipping industry. The import and export of required goods became possible at a large scale only with the help of shipping. More than 45,000 trader vessels are trading globally, moving all types of cargo. Advancement of technology is the reason behind the growing efficiency of ships. It is obvious that even the minimum system downtime in the ships can become the cause of huge loss and costly repairs. Major and minor issues the equipment and system can drastically raise overall operating expenditures. Thus, it is essential to use the highest quality Ground Fault Detector , engine controller, protective relay, generator controller, sensors, and many other devices.   Smart ship owners adopted effective maintenance strategies to ensure smooth operations, reduce downtime and cost and obtain many other advantages. The ship equipment s...

Monitoring Devices and Units to Protect Damages to Electric Systems

There are various protective devices and units available in the market to keep an eye on electrical-systems. These devices are responsible to test, measure and monitor faults, over-currents and short circuits, et cetera. It is important to avoid the failure of such major systems and hazards for individuals and property. This can be done by utilizing preventive and protective devices, such as the insulation monitoring device circuit and fault monitor device, et cetera. Significance of insulation resistance comes into picture when there is a need for prevention of damage and injury to an electrical system. It holds great importance when it comes to ensuring the reliability of electrical systems and equipment. Its role does not end here. It continues as it also serves as an indicator of the condition of an electrical installation. As insulation resistance is important for different purposes, it needs to be tested, measured and monitored. Usually, people get confused with insulation mon...

Have High Resistance Grounding System Solutions of Top Quality

Any electric power system has a tendency of shutting down at some or other points of time. It happens due to certain faults such as over currents and short circuits. These faults may occur due to operation mistakes, ambient conditions, lack of maintenance and atmospheric discharges. It is true that we cannot have control over ambient conditions and atmospheric discharges but still we can adopt available techniques and tools to detect or monitor ground faults. We can utilize ground fault monitor and detector as a protective device to detect fault conditions in order to limit the loss of service due to any failure. Let us discuss more it. Ground Fault – When one of the system phases gets on direct contact to the ground or to any metallic part which is grounded, it results in ground fault. It is important to protect against ground fault because it can result in reduced insulation, physical damages to the insulation system or excessive transient or steady-state voltage stress on insula...